產(chǎn)品闡述
|
Single head system
|
General specifications
|
Sensing range
|
80
... 2000 mm
|
Adjustment range
|
120
... 2000 mm
|
Unusable area
|
0
... 80 mm
|
Standard target plate
|
100
mm x 100 mm
|
Transducer frequency
|
approx.
180 kHz
|
Response delay
|
approx.
150 ms
|
Indicators/operating means
|
LED green
|
solid:
Power-on
flashing: program function object detected
|
LED yellow
|
solid:
switching state switch output
flashing: program function
|
LED red
|
normal
operation: "fault"
program function: no object detected
|
Electrical specifications
|
Operating voltage
|
10
... 30 V DC , ripple 10 %SS
|
No-load supply current
|
≤
50 mA
|
Input/Output
|
Synchronization
|
bi-directional
0
level -UB...+1
V
1 level: +4 V...+UB
input impedance: > 12
KOhm
synchronization pulse: ≥ 100 μs, synchronization interpulse period: ≥ 2
ms
|
Synchronization frequency
|
|
|
Common
mode operation
|
max. 30 Hz
|
|
Multiplex
operation
|
≤ 30/n Hz, n = number of sensors
|
Input
|
Input type
|
1
program input,
operating range 1: -UB ... +1 V, operating range 2: +4 V ... +UB
input impedance: > 4.7 kΩ; program
pulse: ≥ 1 s
|
Output
|
Output type
|
1
switch output NPN , Normally open/closed , programmable
|
Rated operating current
|
200
mA , short-circuit/overload protected
|
Voltage drop
|
≤
2.5 V
|
Repeat accuracy
|
≤
0.5 % of switching point
|
Switching frequency
|
≤
3.3 Hz
|
Range hysteresis
|
1
% of the set operating distance
|
Temperature influence
|
<
2 % of far switch point
|
Approvals and certificates
|
UL approval
|
cULus
Listed, General Purpose
|
CSA approval
|
cCSAus
Listed, General Purpose
|
Ambient conditions
|
Ambient temperature
|
-25
... 70 °C (-13 ... 158 °F)
|
Storage temperature
|
-40
... 85 °C (-40 ... 185 °F)
|
Mechanical specifications
|
Connection type
|
Connector
M12 x 1 , 5-pin
|
Protection degree
|
IP65
|
Material
|
|
|
Housing
|
nickel plated brass; plastic components: PBT
|
|
Transducer
|
epoxy resin/hollow glass sphere mixture; polyurethane
foam
|
Mass
|
140